Foam Attic Air Vents For Eves
Air enters low and then escapes out of the attic higher up near the peak of the roof usually via a ridge vent an attic fan which we do not recommend static roof vents or a high mounted gable vent fan.
Foam attic air vents for eves. For decades the typical solution to this problem was to install ventilation baffles near the eaves connecting the air space above the soffit vents with the attic and then to install as much fluffy insulation usually fiberglass or cellulose as there was room for between the top plate of the exterior wall and the ventilation baffle. Eaves are the undersides of your roof that extend beyond the walls of a building an area commonly directly over decorative plants and vegetation. Foam blocks airflow needs no vapor barrier and has a higher r value per inch than loose fill or batts so you ll get more protection with less depth. Insulation is used in an attic for cross ventilation to minimize potential for moisture accumulation and condensation to help energy savings and moisture control.
Unvented attic assemblies unvented attics rely on an air impermeable insulation installed to the roof deck s underside i e. It can be cut to fit most joist spaces and is an affordable way to meet energy code requirements durovent 22 in. That s why our fire resistant eave vents are especially recommended and in many cases required by california builder code in chapter 7a for the wildland urban interface. The rigid foam is cut to be 2 inches wider than the space between rafters then 1 inch of foam is scored and folded over on either side of the foam creating standoffs that hold the foam away from the roof sheathing providing a space for air to flow.
If the atmospheric combustion appliances start off in a vented attic the building code doesn t require those vents because the appliances are already connected to the outside and should get plenty of air. Then cover the foam with drywall as required for fire safety. The standard intake vent for attics is a soffit vent also sometimes referred to as an eave vent and it allows for air to enter the attic down low near the eaves. Attic ceiling to stop airborne moisture from reaching a cold surface and condensing inside the building envelope in this design insulation effectively separates the interior and exterior spaces while slowing down moisture flow so the dewpoint is not achieved within.
They are typically easier to install and won t detract from the appearance of your roof. Rafter vent 10 pack xudv2248 the home depot. The egv6 power gable mount vent can move air at a rate of up to 1600 cu. For improved air circulation in the attic install the durovent 22 in.
With spray foam unlike with loose fill or batts you must cover the soffit vents they aren t needed to keep the roof cool. Intake air is critical to maintaining a proper flow of air throughout the attic space.